| Peer-Reviewed

DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility

Received: 16 October 2014     Accepted: 30 October 2014     Published: 17 November 2015
Views:       Downloads:
Abstract

This article proposes DIAGRID structural details locked in X-formed steel tube using HSA 800 steel with high tensile strength and superior ductility as a modification of an original DIAGRID version. The structural effectiveness of the new structural DIAGRID detail information is presented in this study using actual nonlinear static pushover analysis.

Published in Applied and Computational Mathematics (Volume 4, Issue 6)
DOI 10.11648/j.acm.20150406.18
Page(s) 452-455
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2015. Published by Science Publishing Group

Keywords

DIAGRID, HSA800, High Tensile Strength, Ductility, Structural System, Nonlinear Pushover Analysis

References
[1] D. K. Lee, J. H. Kim, I. H. Chang, U. Starossek, and S. M. Shin, “Conceptual Layouts and Angles of DiaGrid for Building Frames using Topological Optimization,” Proceedings of the Tenth International Conference on Computational Structures Technology, Civil-Comp Press, Stirlingshire, UK, 2010, paper 317.
[2] K. S. Moon, “Sustainable Design of Diagrid Structural Systems for Tall Buildings,” International Journal of Sustainable Building Technology and Urban Development, vol. 2(1), 2011, pp.37-42.
[3] M. M. Ali and K. S. Moon, “Structural Developments in Tall Buildings: Current Trends and Future Prospects,” Architectural Science Review, vol. 50(3), 2007, pp.205-223.
[4] R. M. Kowalczyk, R. Sinn, and M. B. Kilmister, Structural systems for tall buildings, McGraw-Hill, New York, 1994.
[5] M. M. Ali, “The skyscraper: epitome of human aspirations,” In proceedings of the 7th World Congress of the Council on Tall Buildings and Urban Habitat: Renewing the Urban Landscape [CD-ROM], Chicago, IL: Council on Tall Buildings and Urban Habitat, 2005.
[6] I. McCain, DiaGrid - Structural Efficiency & Increasing Popularity, 2006, http://www.dsg.fgg.uni-lj.si/dubaj2009/.../Diagrid%20technologija.pdf.
[7] A. S. Zimmer and G. R. Bell, John Hancock Center Scaffold Collapse, ASCE Fourth Forensic Engineering Congress, 2006.
[8] R. R. Fayaz, R. M. Mohammad, and K. A. A. Nader, “Modal spectra combination method for pushover analysis of special steel moment resisting frames,” International Journal of Civil Engineering, vol. 10(4), 2012, pp.245-252.
[9] D. H. Kim, S. E. Lee, and J. H. Kim, HSA800: High Strength Steel for Bldgs.: Material Properties and Cost-effectiveness, CTBUH 2012 9th World Congress, 2012. pp.817.
[10] High-performance rolled Steel for building structures, Korea Standard D (KS D) 5994, 2012.
[11] D. K. Lee and S. M. Shin, “Advanced high strength steel tube diagrid using TRIZ and nonlinear pushover analysis,” Journal of Constructional Steel Research, vol. 96, 2014, pp.151-158.
[12] B. Reidar, B, “Development and use of high performance steel,” Journal of Constructional Steel Research, vol. 60(3-5), 2004, pp.393-400.
[13] M. S. Shih and W. P. Sung, “A model for hysteretic behaviour of rhombic low yield strength steel added damping and stiffness,” Computers & Structures, vol. 83(12-13), 2005, pp.895-908.
[14] D. K. Lee, J. H. Lee, J. H. Kim, and U. Starossek, “Investigation on Material Layouts of Structural Diagrid Frames by using Topology Optimization,” KSCE Journal of Civil Engineering vol. 18(2), 2014, pp.549-557.
Cite This Article
  • APA Style

    Dongkyu Lee. (2015). DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility. Applied and Computational Mathematics, 4(6), 452-455. https://doi.org/10.11648/j.acm.20150406.18

    Copy | Download

    ACS Style

    Dongkyu Lee. DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility. Appl. Comput. Math. 2015, 4(6), 452-455. doi: 10.11648/j.acm.20150406.18

    Copy | Download

    AMA Style

    Dongkyu Lee. DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility. Appl Comput Math. 2015;4(6):452-455. doi: 10.11648/j.acm.20150406.18

    Copy | Download

  • @article{10.11648/j.acm.20150406.18,
      author = {Dongkyu Lee},
      title = {DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility},
      journal = {Applied and Computational Mathematics},
      volume = {4},
      number = {6},
      pages = {452-455},
      doi = {10.11648/j.acm.20150406.18},
      url = {https://doi.org/10.11648/j.acm.20150406.18},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.acm.20150406.18},
      abstract = {This article proposes DIAGRID structural details locked in X-formed steel tube using HSA 800 steel with high tensile strength and superior ductility as a modification of an original DIAGRID version. The structural effectiveness of the new structural DIAGRID detail information is presented in this study using actual nonlinear static pushover analysis.},
     year = {2015}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - DIAGRID Generation Applied to X-shape Steel Tube of HSA800 with High Tensile Strength and Ductility
    AU  - Dongkyu Lee
    Y1  - 2015/11/17
    PY  - 2015
    N1  - https://doi.org/10.11648/j.acm.20150406.18
    DO  - 10.11648/j.acm.20150406.18
    T2  - Applied and Computational Mathematics
    JF  - Applied and Computational Mathematics
    JO  - Applied and Computational Mathematics
    SP  - 452
    EP  - 455
    PB  - Science Publishing Group
    SN  - 2328-5613
    UR  - https://doi.org/10.11648/j.acm.20150406.18
    AB  - This article proposes DIAGRID structural details locked in X-formed steel tube using HSA 800 steel with high tensile strength and superior ductility as a modification of an original DIAGRID version. The structural effectiveness of the new structural DIAGRID detail information is presented in this study using actual nonlinear static pushover analysis.
    VL  - 4
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Department of Architectural Engineering, Sejong University, Seoul, South Korea

  • Sections